☰ Menu
Cisco DS-C9124V-8IK9 Network Switch front view

Cisco · Network Switch

DS-C9124V-8IK9 Cisco MDS 9124V 64-Gbps 24-Port Fibre Channel Switch

Model: DS-C9124V-8IK9|Condition: Original New|Warranty: 1 year

The Cisco DS-C9124V-8IK9 is stocked by ImportGM for resellers, MSPs and enterprise buyers sourcing genuine network switches with export-ready documentation. Cisco MDS 9124V 64-Gbps 24-Port Fibre Channel switch brings the latest high-performance, low-latency Fibre Channel Storage Area Network (SAN) technology to market. Along with the higher bandwidth, the Cisco MDS 9124V switch supports ease of configuration and management, detailed and in-depth performance insights, and automation capabilities. Core parameters include fibre channel ports ● Fixed-switch form factor with 24 SFP+ ports base. Original New units carry the 1 year ImportGM warranty; quotation, proforma invoice and export packing list are issued the same day.

  • ✔Cisco 9124V 64-Gbps 24 Port Fibre Channel Switch
  • ✔Main features and benefits
  • ✔● Next-generation ASIC: The MDS 9124V Fibre Channel switch is powered by Cisco developed next- generation high-performance 64G ASIC.
  • ✔● Higher scalability: Increased fabric scalability provides more flexibility for a variety of SAN architectures.
  • ✔SAN architecture benefits
  • ✔Comprehensive solution for Robust Network Security

Bulk pricing available · Export packing & documentation · DHL / FedEx / air / sea freight

Technical Specifications

FeatureDescription
Product compatibilityCisco MDS 9000 Family
Software compatibilityCisco MDS 9000 NX-OS Release 9.3(1) or later
Protocols● Fibre Channel standards● FC-PI-6 (INCITS 512-2015)● FC-PI-7 (INCITS 543-2019)● FC-FS-4 (INCITS 488-2016)● FC-FS-5 (INCITS 545-2019)● FC-GS-7 (INCITS 510-2017)● FC-GS-8 (INCITS 548-2020)● FC-LS-3 (INCITS 487-2018)● FC-LS-4 (INCITS 553-2020)● FC-SW-6 (INCITS 511-2016)● FC-SW-7 (INCITS 547-2020)● NVMe/FC (INCITS 540-2018)● NVMe/FC-2 (INCITS 556-2020)● FC-PH, Revision 4.3 (ANSI INCITS 230-1994)● FC-PH, Amendment 1 (ANSI INCITS 230-1994/AM1-1996)● FC-PH, Amendment 2 (ANSI INCITS 230-1994/AM2-1999)● FC-PH-2, Revision 7.4 (ANSI INCITS 297-1997)● FC-PH-3, Revision 9.4 (ANSI INCITS 303-1998)● FC-PI, Revision 13 (ANSI INCITS 352-2002)● FC-PI-2, Revision 10 (ANSI INCITS 404-2006)● FC-PI-3, Revision 4 (ANSI INCITS 460-2011)● FC-PI-4, Revision 8 (ANSI INCITS 450-2008)● FC-PI-5, Revision 6 (ANSI INCITS 479-2011)● FC-FS, Revision 1.9 (ANSI INCITS 373-2003)● FC-FS-2, Revision 1.01 (ANSI INCITS 424-2007)● FC-FS-2, Amendment 1 (ANSI INCITS 424-2007/AM1-2007)● FC-FS-3, Revision 1.11 (ANSI INCITS 470-2011)● FC-FS-4● F-LS, Revision 1.62 (ANSI INCITS 433-2007)● FC-LS-2, Revision 2.21 (ANSI INCITS 477-2011)● FC-LS-3, Includes revision 3.53● FC-SW-2, Revision 5.3 (ANSI INCITS 355-2001)● FC-SW-3, Revision 6.6 (ANSI INCITS 384-2004)● FC-SW-4, Revision 7.5 (ANSI INCITS 418-2006)● FC-SW-5, Revision 8.5 (ANSI INCITS 461-2010)● FC-SW-6● FC-GS-3, Revision 7.01 (ANSI INCITS 348-2001)● FC-GS-4, R evision 7.91 (ANSI INCITS 387-2004)● FC-GS-5, Revision 8.51 (ANSI INCITS 427-2007)● FC-GS-6, Revision 9.4 (ANSI INCITS 463-2010)● FC-GS-7, Includes revision 10.8● FCP, Revision 12 (ANSI INCITS 269-1996)● FCP-2, Revision 8 (ANSI INCITS 350-2003)● FCP-3, Revision 4 (ANSI INCITS 416-2006)● FCP-4, Revision 2b (ANSI INCITS 481-2011)● FC-SB-2, Revision 2.1 (ANSI INCITS 349-2001)● FC-SB-3, Revision 1.6 (ANSI INCITS 374-2003)● FC-SB-3, Amendment 1 (ANSI INCITS 374-2003/AM1-2007)● FC-SB-4, Revision 3.0 (ANSI INCITS 466-2011)● FC-SB-5, Revision 2.00 (ANSI INCITS 485-2014)● FC-BB-2, Revision 6.0 (ANSI INCITS 372-2003)● FC-BB-3, Revision 6.8 (ANSI INCITS 414-2006)● FC-BB-4, Revision 2.7 (ANSI INCITS 419-2008)● FC-BB-5, Revision 2.0 (ANSI INCITS 462-2010)● FC-BB-6, Revision 2.00 (ANSI INCITS 509-2014)● FC-VI, Revision 1.84 (ANSI INCITS 357-2002)● FC-SP, Revision 1.8 (ANSI INCITS 426-2007)● FC-SP-2, Revision 2.71 (ANSI INCITS 496-2012)● FAIS, Revision 1.03 (ANSI INCITS 432-2007)● FAIS-2, Revision 2.23 (ANSI INCITS 449-2008)● FC-IFR, Revision 1.06 (ANSI INCITS 475-2011)● FC-FLA, Revision 2.7 (INCITS TR-20-1998)● FC-PLDA, Revision 2.1 (INCITS TR-19-1998)● FC-Tape, Revision 1.17 (INCITS TR-24-1999)● FC-MI, Revision 1.92 (INCITS TR-30-2002)● FC-MI-2, Revision 2.6 (INCITS TR-39-2005)● FC-MI-3, Revision 1.03 (INCITS TR-48-2012)● FC-DA, Revision 3.1 (INCITS TR-36-2004)● FC-DA-2, Revision 1.06 (INCITS TR-49-2012)● FC-MSQS, Revision 3.2 (INCITS TR-46-2011)● Fibre Channel classes of service: Class 2, Class 3, and Class F● Fibre Channel standard port types: E and F● Fibre Channel enhanced port types: SD, ST, NP and TE● NVMe/FC● In-band management using IP over Fibre Channel (RFC 2625)● IPv6, IPv4, and Address Resolution Protocol (ARP) over Fibre Channel (RFC 4338)● Extensive IETF-standards based TCP/IP, SNMPv3, and remote monitoring (RMON) MIBs
Fibre Channel ports● Fixed-switch form factor with 24 SFP+ ports base
Security● VSAN fabric isolation● Intelligent packet inspection at port level● Hardware zoning by Access Control Lists (ACLs)● Fibre Channel Security Protocol (FC-SP) switch-to-switch authentication● FC-SP host-to-switch authentication● Role-Based Access Control (RBAC) using RADIUS, TACACS+, or Lightweight Directory Access Protocol (LDAP) authentication, authorization, and accounting (AAA) functions● Secure FTP (SFTP)● Secure Shell Protocol Version 2 (SSHv2)● Simple Network Management Protocol Version 3 (SNMPv3) implementing Advanced Encryption Standard (AES)● Control-plane security● Cisco TrustSec ® payload encryption● Secure Boot and Anti-counterfeit technology
Performance● Port speed: 8-, 16-, 32 and 64-Gbps autosensing with 64 Gbps of dedicated bandwidth per port● Aggregate bandwidth of 1.5-Tbps end-to-end full duplex● Buffer credits: Up to 24,000 for a group of 24 ports, with a default of 1000 buffer credits per port and a maximum of 16,000 buffer credits for a single port in the group● Port groups: 1 port group of 24 ports● Port channel: Up to 24 load-balanced physical links grouped in one port channel
Diagnostics● Power-On-Self-Test (POST) diagnostics● Online Health Management System (OHMS) diagnostics● Internal loopbacks● SPAN● Fibre Channel traceroute● Fibre Channel ping● Fibre Channel debug● Cisco Fabric Analyzer● Syslog● Port-level statistics● Link diagnostics (E-port and F-port links)● Read Diagnostic Parameter
Serviceability● Configuration file management● Call Home● Port beaconing● Link cable beacon● System LEDs● SNMP traps for alerts
Reliability and availability● Cisco In-Service Software Upgrade (ISSU)● Hot-swappable, dual redundant power supplies● Hot-swappable fan tray with switch integrated temperature and power management● Hot-swappable SFP+ optics● Stateful process restart● Any port configuration for port channels● Fabric-based multipathing● Per-VSAN fabric services● Port tracking● FEC with HBA ports● Buffer-to-buffer state change notification with HBA ports
Network management● Management access through the following out-of-band Ethernet ports ◦ mgmt0: 10/100/1000BASE-T port ● RS-232 serial console port● USB power-on auto-provision port● Access protocols● Command-Line Interface (CLI) using the console and Ethernet port● SNMPv3 using the Ethernet port and in-band IP over Fibre Channel access● Storage Networking Industry Association (SNIA) Storage Management Initiative Specification (SMI-S)● NX-API for HTTP/HTTPS full programmability● Distributed device alias service● Network security● Per-VSAN RBAC using LDAP, RADIUS, and TACACS+-based AAA functions● Simple File Transfer Protocol (SFTP)● SSHv2 implementing AES● SNMPv3 implementing AES
Programming interfaces● Scriptable CLI● Cisco DCNM/NDFC web services API● NX-API HTTP/HTTPS interfaces● Onboard Python interpreter● Cisco Embedded Event Manager (EEM)● Cisco NX-OS Software scheduler
Physical dimensions (H x W x D) and weight● 1 Rack Unit (1RU) (1.72 x 17.299 x 18 in. [4.37 x 43.94 x 45.72 cm]) excluding Power Supply Unit (PSU) and fan-tray handles● 18.73 lb. (8.5 kg)
Power● 80 Plus Platinum certified power supplies● Power supply options ◦ 500W AC in base model, port-side exhaust variant (2 per switch) ◦ 500W AC in base model, port-side intake variant (2 per switch) ◦ 1200W AC/ HVAC/ HVDC in base model, Bidirectional airflow (2 per switch) ● Power cord ◦ Notched C15 socket connector connecting to C16 plug on the power supply receptacle for 500W Power Supply ◦ Standard CAB-HVAC-C14-2M IEC C14 to Saf-d-grid connector on the power supply receptacle for 1200W Power Supply ◦ Check Ordering Information table in this document for power cords specific to regions ● 500W PSU AC input: 100 to 240 VAC (10% range)● 1200W PSU AC input: 90V to 305V● 1200W PSU DC input: 192V to 400V● Frequency: 50 to 60 Hz (nominal)● Typical power consumption ◦ 94W for 24-Port switch in idle status with no optics modules ◦ 113W for 24-Port switch with 8 64G SW optics modules under 50% line rate ◦ 146W for 24-Port switch with 24 64G SW optics modules under 50% line rate ● Airflow ◦ Back to front (toward ports) using port-side exhaust fans ◦ Front to back (inward from ports) using port-side intake fans ◦ 50 Cubic Feet per Minute (CFM) through system fan assembly at 77°F (25°C) ● 100 CFM maximum
Temperature range● Temperature, ambient operating: ◦ 32 to 104°F (0 to 40°C) with port-side exhaust and intake airflow variants ● Temperature, ambient nonoperating and storage: –40° to 158°F (–40° to 70°C)● Relative humidity, ambient (noncondensing) operating: 10% to 90%● Relative humidity, ambient (noncondensing) nonoperating and storage: 10% to 95%● Altitude, operating: –197 to 6500 ft (–60 to 2000m)
Approvals and compliance● Safety compliance● CE Marking● UL 60950● CAN/CSA-C22.2 No. 60950● EN 60950● IEC 60950● TS 001● AS/NZS 3260● IEC60825● EN60825● 21 CFR 1040● EMC compliance● FCC Part 15 (CFR 47) Class A● ICES-003 Class A● EN 55022 Class A● CISPR 22 Class A● AS/NZS 3548 Class A● VCCI Class A● EN 55024● EN 50082-1● EN 61000-6-1● EN 61000-3-2● EN 61000-3-3
Fabric services● Name server● Registered State Change Notification (RSCN)● Login services● Fabric Configuration Server (FCS)● Broadcast● In-order delivery
Advanced functions● VSAN● IVR● NPV● Port Channel with multipath load balancing● Flow- and zone-based QoS

Product Overview

Cisco MDS 9124V 64-Gbps 24-Port Fibre Channel switch brings the latest high-performance, low-latency Fibre Channel Storage Area Network (SAN) technology to market. Along with the higher bandwidth, the Cisco MDS 9124V switch supports ease of configuration and management, detailed and in-depth performance insights, and automation capabilities.

The next-generation Cisco MDS 9124V 64-Gbps 24-Port Fibre Channel Switch (Figure 1) provides high-speed Fibre Channel connectivity for all-flash arrays and high-performance hosts. This switch offers state-of-the-art analytics and telemetry capabilities built into its next-generation Application-Specific Integrated Circuit (ASIC) chipset. This switch allows seamless transition to Fibre Channel Non-Volatile Memory Express (NVMe/FC) workloads whenever available without any hardware upgrade in the SAN. It empowers small, midsize, and large enterprises that are rapidly deploying cloud-scale applications using extremely dense virtualized servers, providing the benefits of greater bandwidth, scale, and consolidation. Some of the main benefits for a small-scale Storage Area Network (SAN) are automatic zoning, nonblocking forwarding and a single port group of 24 ports. Benefits for a mid- to large-size SAN include higher scale for Fibre Channel control-plane functions, Virtual SANs, fabric login (FLOGI), device alias and name server scale, 24 ports of 64-Gbps non-oversubscribed line-rate ports, bidirectional airflow, and a fixed-form NVMe/FC-ready SAN switch with enhanced Buffer-to-Buffer (B2B) credits and capable of hardware-assisted Fibre Channel link encryption. Large-scale SAN architectures built with SAN core directors can expand 64-Gbps connectivity to the server rack using these switches configured in either switch mode or Network Port Virtualization (NPV) mode. Additionally, the switch supports enhanced diagnostic features such as Inter-Switch Link (ISL) and Host-Bus-Adapter (HBA) diagnostics, remote SFP (Read Diagnostic Parameter) diagnostics, remote port beaconing (Link Cable Beaconing) and advanced reliability features such as link level Forward Error Correction (FEC) with HBA ports.

● High performance: MDS 9124V architecture, with nonblocking arbitration, provides consistent 64-Gbps low-latency performance across all traffic conditions for every Fibre Channel port on the switch.

● Fully integrated SAN Analytics: This feature-rich switch also offers state-of-the-art data traffic analytics and telemetry capabilities that have been built into this next-generation hardware platform. This new state-of-the-art technology couples the next-generation port ASIC with a fully dedicated Network Processing Unit (NPU). Information is extracted by the port ASIC from passing line rate traffic and used by the NPU to calculate performance data on board the switch in real time. Using an industry-leading open telemetry format, the data can be streamed to any analytics visualization platform.

● Cisco Dynamic Ingress Rate Limiting (DIRL): MDS 9124V supports the dynamic ingress rate limiting feature. Using DIRL, the MDS SAN can automatically detect any symptoms of congestion and then dynamically rate limits the congested and slow-drain devices so that adverse effects are not spread to other devices. DIRL dynamically adapts the rate-limiting to suit the traffic profile of the congestion or slow-drain device.

● Capital Expenditures (CapEx) savings: The 64-Gbps ports allow users to deploy them with existing 32- or 16-Gbps transceivers providing investment protection, with an option to upgrade to 64-Gbps transceivers and adapters whenever needed.

About Network Switchs from ImportGM

Campus access, aggregation and core switches — PoE+, multi-gigabit and 10G/25G/40G/100G platforms from Cisco, H3C, Alcatel-Lucent, Ruckus, Aruba, Huawei and Fortinet. All units genuine, serial traceable and export ready.

Browse all Network Switchs →