ImportGM supplies the Cisco DS-X9334-K9, a network module & card built for campus, branch and data centre networks, to distributors, system integrators and enterprise IT procurement teams across Europe, North America and the Middle East. The Cisco MDS 9000 24/10-Port SAN Extension Module provides a high-performance, flexible, unified platform for deploying enterprise-class disaster-recovery and business-continuance SAN extension solutions (Figure 1). Core parameters include programming interfaces ● Cisco Data Center Network Manager GUI● Cisco Device Manager GUI. Original New units carry the 1 year ImportGM warranty; quotation, proforma invoice and export packing list are issued the same day.

  • ✔Cisco MDS 9000 24/10-Port SAN Extension Module
  • ✔Main features and benefits
  • ✔● FCIP for remote SAN extension
  • ✔● I/O Accelerator Services
  • ✔◦ Unified solution for disk and tape I/O acceleration over Metropolitan Area Networks (MANs) and WANs
  • ✔◦ Extension of acceleration as a fabric service to any port in the fabric, regardless of where it is attached

Bulk pricing available · Export packing & documentation · DHL / FedEx / air / sea freight

Technical Specifications

FeatureDescription
Product compatibilityCisco MDS 9000 Family
Software compatibilityCisco MDS 9000 NX-OS Software 7.3(0)DY(1)
ProtocolsFibre Channel standards ● FC-PH, Revision 4.3 (ANSI INCITS 230-1994)● FC-PH, Amendment 1 (ANSI INCITS 230-1994/AM1-1996)● FC-PH, Amendment 2 (ANSI INCITS 230-1994/AM2-1999)● FC-PH-2, Revision 7.4 (ANSI INCITS 297-1997)● FC-PH-3, Revision 9.4 (ANSI INCITS 303-1998)● FC-PI, Revision 13 (ANSI INCITS 352-2002)● FC-PI-2, Revision 10 (ANSI INCITS 404-2006)● FC-PI-3, Revision 4 (ANSI INCITS 460-2011)● FC-PI-4, Revision 8 (ANSI INCITS 450-2008)● FC-PI-5, Revision 6 (ANSI INCITS 479-2011)● FC-FS, Revision 1.9 (ANSI INCITS 373-2003)● FC-FS-2, Revision 1.01 (ANSI INCITS 424-2007)● FC-FS-2, Amendment 1 (ANSI INCITS 424-2007/AM1-2007)● FC-FS-3, Revision 1.11 (ANSI INCITS 470-2011)● FC-LS, Revision 1.62 (ANSI INCITS 433-2007)● FC-LS-2, Revision 2.21 (ANSI INCITS 477-2011)● FC-SW-2, Revision 5.3 (ANSI INCITS 355-2001)● FC-SW-3, Revision 6.6 (ANSI INCITS 384-2004)● FC-SW-4, Revision 7.5 (ANSI INCITS 418-2006)● FC-SW-5, Revision 8.5 (ANSI INCITS 461-2010)● FC-GS-3, Revision 7.01 (ANSI INCITS 348-2001)● FC-GS-4, Revision 7.91 (ANSI INCITS 387-2004)● FC-GS-5, Revision 8.51 (ANSI INCITS 427-2007)● FC-GS-6, Revision 9.4 (ANSI INCITS 463-2010)● FCP, Revision 12 (ANSI INCITS 269-1996)● FCP-2, Revision 8 (ANSI INCITS 350-2003)● FCP-3, Revision 4 (ANSI INCITS 416-2006)● FCP-4, Revision 2b (ANSI INCITS 481-2011)● FC-SB-2, Revision 2.1 (ANSI INCITS 349-2001)● FC-SB-3, Revision 1.6 (ANSI INCITS 374-2003)● FC-SB-3, Amendment 1 (ANSI INCITS 374-2003/AM1-2007)● FC-SB-4, Revision 3.0 (ANSI INCITS 466-2011)● FC-SB-5, Revision 2.00 (ANSI INCITS 485-2014)● FC-BB-6, Revision 2.00 (ANSI INCITS 509-2014)● FC-BB-2, Revision 6.0 (ANSI INCITS 372-2003)● FC-BB-3, Revision 6.8 (ANSI INCITS 414-2006)● FC-BB-4, Revision 2.7 (ANSI INCITS 419-2008)● FC-BB-5, Revision 2.0 (ANSI INCITS 462-2010)● FC-VI, Revision 1.84 (ANSI INCITS 357-2002)● FC-SP, Revision 1.8 (ANSI INCITS 426-2007)● FC-SP-2, Revision 2.71 (ANSI INCITS 496-2012)● FAIS, Revision 1.03 (ANSI INCITS 432-2007)● FAIS-2, Revision 2.23 (ANSI INCITS 449-2008)● FC-IFR, Revision 1.06 (ANSI INCITS 475-2011)● FC-FLA, Revision 2.7 (INCITS TR-20-1998)● FC-PLDA, Revision 2.1 (INCITS TR-19-1998)● FC-Tape, Revision 1.17 (INCITS TR-24-1999)● FC-MI, Revision 1.92 (INCITS TR-30-2002)● FC-MI-2, Revision 2.6 (INCITS TR-39-2005)● FC-MI-3, Revision 1.03 (INCITS TR-48-2012)● FC-DA, Revision 3.1 (INCITS TR-36-2004)● FC-DA-2, Revision 1.06 (INCITS TR-49-2012)● FC-MSQS, Revision 3.2 (INCITS TR-46-2011)● Fibre Channel classes of service: Class 2, Class 3, and Class F● Fibre Channel standard port types: E, F, FL, and B● Fibre Channel enhanced port types: SD, ST, and TE● IP over Fibre Channel (RFC 2625)● IPv6, IPv4, and Address Resolution Protocol (ARP) over Fibre Channel (RFC 4338)● Extensive IETF-standards based TCP/IP, SNMPv3, and remote monitoring (RMON) MIBs IP standards ● RFC 791 IPv4● RFC 793 and 1323 TCP● RFC 894 IP/Ethernet● RFC 1041 IP/802● RFC 792, 950, and 1256 Internet Control Message Protocol (ICMP)● RFC 1323 TCP performance enhancements● RFC 2338 Virtual Router Redundancy Protocol (VRRP)● RFC 2460 and 4291 IPv6● RFC 2463 ICMPv6● RFC 2461 and 2462 IPv6 neighbor discovery and stateless autoconfiguration● RFC 2464 IPv6/Ethernet● RFC 3643 and 3821 FCIP Ethernet standards ● IEEE 802.3z Gigabit Ethernet● IEEE 802.1Q VLAN IPsec standards ● RFC 2401 Security Architecture for IP● RFC 2403 and 2404 Hash Message Authentication Code (HMAC)● RFC 2405, 2406, and 2451 IP Encapsulating Security Payload (ESP)● RFC 2407 and 2408 Internet Security Association and Key Management Protocol (ISAKMP)● RFC 2412 OAKLEY Key Determination Protocol● RFC 3566, 3602, and 3686 AES Internet Key Exchange (IKE) standards ● RFC 2409 IKEv1● IKEv2, draft
Cards, ports, and slots24 x fixed 2/4/8/10/16-Gbps Fibre Channel ports, 8 x 1/10 Gigabit Ethernet ports, 2 x 40 Gigabit Ethernet port
Fabric services● Name server● Registered State Change Notification (RSCN)● Login services● Cisco Fabric Configuration Server (FCS)● Private loop● Public loop● Translative loop● Broadcast● In-order delivery
Advanced functions● VSAN● IVR● Port channel with multipath load balancing● Flow-based and zone-based QoS● Hardware-based compression for MAN and WAN data● Hardware-based encryption● Hardware-based data integrity● FCIP disk write acceleration● FCIP tape read and write acceleration
Diagnostics and troubleshooting tools● POST diagnostics● Online diagnostics● Internal port loopbacks● SPAN and remote SPAN● Fibre Channel Traceroute● Fibre Channel Ping● Fibre Channel Debug● Cisco Fabric Analyzer● Syslog● Online system health● Port-level statistics● Real-Time Protocol (RTP) debug
Network security● VSANs● ACLs● Per-VSAN RBAC● Fibre Channel zoning ◦ N-port worldwide name (WWN) ◦ N-port FC-ID ◦ Fx-port WWN ◦ Fx-port WWN and interface index ◦ Fx-port domain ID and interface index ◦ Fx-port domain ID and port number ◦ Logical Unit Number (LUN) ◦ Read-only ◦ Broadcast ● FC-SP ◦ DH-CHAP switch-to-switch authentication ◦ DH-CHAP host-to-switch authentication ● Port security and fabric binding● IPsec for FCIP● IKEv1 and v2● Management access ◦ SSH v2 implementing AES ◦ SNMPv3 implementing AES ◦ SFTP
Serviceability● Configuration file management● Nondisruptive software upgrades for Fibre Channel interfaces● Call Home● Power-management LEDs● Port beaconing● System LED● SNMP traps for alerts● Network boot
Performance● Port speed: Fibre Channel 2/4/8/10/16 Gbps; FCIP 1/10 Gigabit Ethernet● Port channels: Up to 16 FCIP links● FCIP tunnels: Up to 3 per port
Reliability and availability● Hot-swappable module● Hot-swappable SFP optics● Online diagnostics● Stateful process restart● Nondisruptive supervisor failover● Any module, any port configuration for port channels● Fabric-based multipathing● Per-VSAN fabric services● Port tracking● VRRP for management and FCIP
Network management● Access methods through Cisco MDS 9700 Series Supervisor Module ◦ Out-of-band 10/100/1000 Ethernet port (Supervisor-1 Module) ◦ Out-of-band 10/100/1000 Ethernet port (Supervisor-2 Module) ◦ RS-232 serial console port (RJ45 form factor) ◦ In-band IP-over-Fibre Channel ● Access protocols ◦ Command-Line Interface (CLI) through console and Ethernet ports ◦ SNMPv3 through Ethernet port and in-band IP-over-Fibre Channel access ◦ Storage Networking Industry Association (SNIA) Storage Management Initiative Specification (SMI‑S) ● Distributed device alias service● Network security ◦ Per-VSAN RBAC using RADIUS- and TACACS+-based Authentication, Authorization, and Accounting (AAA) functions ◦ SFTP ◦ SSHv2 implementing AES ◦ SNMPv3 implementing AES ● Management applications ◦ Cisco MDS 9000 Family CLI ◦ Cisco Data Center Network Manager ◦ Cisco Device Manager
Programming interfaces● Cisco Data Center Network Manager GUI● Cisco Device Manager GUI
Environmental● Temperature, ambient operating: 32 to 104°F (0 to 40°C)● Temperature, ambient nonoperating and storage: –40 to 158°F (–40 to 70°C)● Relative humidity, ambient (noncondensing) operating: 5 to 90%● Relative humidity, ambient (noncondensing) nonoperating and storage: 5 to 95%● Altitude, operating: –197 to 6500 ft (–60 to 2000m)
Physical dimensions● Dimensions (H x W x D): 1.75 x 15.9 x 21.8 in. (4.4 x 40.39 x 55.37 cm) Occupies one slot in a Cisco MDS 9700 Series● Weight: 17 lb (7.71 kg)
Approvals and compliance● Safety compliance ◦ CE Marking ◦ UL 60950 ◦ CAN/CSA-C22.2 No. 60950 ◦ EN 60950 ◦ IEC 60950 ◦ TS 001 ◦ AS/NZS 3260 ◦ IEC60825 ◦ EN60825 ◦ 21 CFR 1040 ● EMC compliance ◦ FCC Part 15 (CFR 47) Class A ◦ ICES-003 Class A ◦ EN 55022 Class A ◦ CISPR 22 Class A ◦ AS/NZS 3548 Class A ◦ VCCI Class A ◦ EN 55024 ◦ EN 50082-1 ◦ EN 61000-6-1 ◦ EN 61000-3-2 ◦ EN 61000-3-3

Product Overview

The Cisco MDS 9000 24/10-Port SAN Extension Module provides a high-performance, flexible, unified platform for deploying enterprise-class disaster-recovery and business-continuance SAN extension solutions (Figure 1).

The MDS 9000 24/10-Port SAN Extension Module is supported on Cisco MDS 9700 Series Multilayer Directors. With 24 line-rate 2-, 4-, 8-, 10-, and 16-Gbps Fibre Channel ports and eight 1 and 10 Gigabit Ethernet Fibre Channel over IP (FCIP) ports, this module enables large and scalable deployment of SAN extension solutions. The SAN extension module has two independent service engines that can each be individually and incrementally enabled to scale as business requirements expand. The SAN extension module supports the full range of services available on other Cisco MDS 9000 Family Fibre Channel switching modules, including virtual SAN (VSAN), security, and traffic management services. The FCIP module uses Cisco expertise and knowledge of IP networks to deliver outstanding SAN extension performance, reducing latency for disk and tape operations with FCIP acceleration features, including FCIP write acceleration and FCIP tape write and read acceleration. Hardware-based encryption helps secure sensitive traffic with IP Security (IPsec), and hardware-based compression dramatically enhances performance for both high- and low-speed links, enabling immediate cost savings in expensive WAN infrastructure. Multiple FCIP interfaces within a single engine or across service engines can be grouped into a port channel of up to 16 links for high availability and increased aggregate throughput.

◦ Simplifies data-protection and business-continuance strategies by enabling backup, remote replication, and other disaster-recovery services over WAN distances using open standards FCIP tunneling.

◦ Optimizes utilization of WAN resources for backup and replication by enabling hardware-based compression, hardware-based encryption, FCIP write acceleration, and tape read and write acceleration for both FCIP and FICON over IP. The SAN extension module will support 3 tunnels per interface and can scale up to 24 tunnels (3 tunnels x 8 1/10GE ports).

◦ Preserves MDS 9000 Family enhanced capabilities, including VSANs, advanced traffic management, and security, across remote connections.

◦ Transport and Speed-independent acceleration that accelerates Disk and Tape traffic over any 2/4/8/16G Fibre Channel port on the director and 1/10GE FCIP ISLs